Product release

Product line
Access control
Category
Product release
Date
November 16th, 2026

Product Release: Omnis E100 Firmware 7.7.8

Acre Security is pleased to announce the release of Omnis E100 Firmware version 7.7.8, available as of November 16th 2026.
This release strengthens the Omnis E100's cybersecurity posture.
It addresses a security vulnerability in the bundled PHP component and closes a cybersecurity compliance gap. It also updates a wide range of third-party components to keep the platform secure and up to date. The update also corrects the handling of "Door Forced" events when opening a door that is already open. Furthermore, it ensures that network settings are preserved during an SD card factory reset.

The software can be downloaded from our Products page, under the Software-tab for both the E100 and E100-S.     

What’s new?

The following changes have been implemented.

• Security: PHP 8.2.30 → 8.2.35 (CVE-2026-109618, CVE-2026-109619), plus updates to a broad set of third-party components.

• Keep network settings on factory reset. Add /firmware/keep_network_settings alongside /firmware/factory on the SD card to retain network settings and the web interface certificate.

• Per-device web certificate. A device-specific self-signed certificate is generated when none is installed, replacing the legacy shared default certificates.

• Compliance: Required step towards EU Cyber Resilience Act (CRA) compliance.

Bug Fixes

• False ‘Door Forced’ events during normal openings, including when access is granted while the door is already open.

• Log events from backbone-connected units sometimes not reaching the PC.

• Temporary door unlocks not cancelled on a stop or access-denied indication.

• Lock-strike and motor-strike relays activating while their alarm area is set.

• Users able to run control functions from a MAP control panel without access rights.

• Aperio message handling continuing after corrupt data was discarded.

• Network discovery stopping when a scan runs right after the network connection comes up.

Related Products

Article No.DescriptionProduction FirmwareDownloadable Firmware
V54502-F101-A100E100 Central Controller7.6.4 (LON app v61)7.7.8 (LON App v63)
V54502-F103-A100E100-S Satellite Controller7.6.4 (LON app v61)7.7.8 (LON App v63)

 

Product release

Security updates 

PHP 8.2.30 → 8.2.35 is the primary driver. It fixes memory corruption during out-of-memory handling and stale state between requests, which can lead to remote code execution under affected configurations (CVE-2026-109618, CVE-2026-109619).

Other updates

• Dropbear 2025.89 → 2026.94: CVE-2019-6111, CVE-2026-35385.

• mbedTLS 3.6.6 → 3.6.7: CVE-2026-50640.

• lighttpd 1.4.82 → 1.4.85: hardened request-header handling and Content-Length validation.

• glibc 2.39-261 → 2.39-299: 9 CVEs, with additional backports.

• Linux kernel: fixes and mitigations for 45 CVEs.

• Also: GnuPG (CVE-2025-68973), BusyBox, SQLite, sudo, zlib, iptables 1.8.13, PCRE2 10.48.

Customer Impact

• All users: Update recommended.

• 7.7.8 removes the unnecessary ‘Door Forced’ events caused by opening an already open door in 7.7.7.

• Web certificate: Installations that relied on the legacy shared default certificate may present a different certificate after upgrading. Installers should be made aware.

• Rollback: Possible via SD card. No other products or components are recorded as impacted.

How to Upgrade

The following methods are available for upgrading units in the field.

E100 Firmware

1: Upgrade using SD-card - This method can be used to upgrade the E100/E100-S, but not the LON-board. See below for methods to upgrade the LON-board.

2: Upgrade using E100 Web Interface – This method can be used to upgrade the E100/E100-S, E200, and the LON-board. See below for more details.

LON-board Firmware

The LON app can be upgraded using one of the following methods.

1. Upgrade using USB LON-Module – This method can be used to upgrade the LON-board with an additional piece of 3rd party hardware (not sold by acre Security): U10 USB Network Interface – TP/FT-10 Channel.

2. LON-Board swap between E200 and E100 – This method can be used to upgrade the E100/E100-S’s LON-board without the use of a LON-module. For instructions, please see manual: A-100435-10_Omnis_Discovery_and_Web_Tool-EN-SV.

View as PDF